dutec Innovative Technology
 
Same Day Shipping 800-248-1632
Specifications: BMFBR to RS232/485/422  

 
 
Isolation

Electromagnetic: Power-to-RS-232/422/485, Power-to-Chassis, RS-232/422/485-to-Chassis.
Hi-Pot: 1500VRMS for 1minute, xxxx VDC for 1 second
Leakage Current: Less than xxxuA @ 1500VAC / 60Hz; xxxx VDC

Baud Rate 0 to 115Kbps
Range

RS-422 and RS-485 4000 Ft (1.23kM) @ 38.4Kbps using 24AWG twisted pair
Optical - Up to 1.2 Miles (2kM)

Weight

13.5 oz. (383 Grams)

Power

7 to 24 Volts AC / 9 to 36 Volts DC @ 155mA (max)
9 VDC @ 155 mA (max)
12 VDC @ 110 mA (max)
24 VDC @ 60 mA (max)
36 VDC @ 40 mA (max)

Enclosure

18 Gage Stainless Steel Type 304

Dimensions Height: 4.6 Inches (117mm)
Depth: 4.16 Inches (106mm)
Width: 1.00 Inch (25mm)
RS-485/422

Supports RS-422, 2 or 4 wire, RS-485 Autodetect
Input resistance: 12KS to 15KS (single unit load)

RS-485 Enable Automatic, Patented ADFCTM technology automatically controls data flow direction
RS-232 Supports TxD, RxD, DTR, DSR, RTS, CTS, DCD
Connector: DB9 male or female
DCE or DTE selectable
Short circuit protected
Input resistance: 3KS to 7KS
ESD tolerance > +/-15kV
Optical Transmitter 820 nm LED, Type ST connector, IEC AEL class 1, Output Power -22.2 to -6.9 dBm
(min.) depending on model and fiber type.
650 nm LED, Type ST or SMA connector, IEC AEL class 1, Output Power -7.5 dBm
(POF), -18.0 dBm (HCS)
Optical Receiver

820 nm, Type ST connector, -24 dBm minimum input
650 nm, Type ST or SMA connector, -21.6 dBm (POF), -23dBm (HCS)

Operating
Temperature
-25°C to +80°C
Storage Temperature

-45°C to +100°C

Humidity 5% to 95% RH
Compliance Pending (CE, FCC Class A, CUL, UL safety Class II)
Accessories Din Rail Mounting Kit P/N DA-01
AC Power Adapter: North American 120V input P/N BM-PS120
AC Power Adapter: European Universal input 90 to 264 VAC P/N BM-PSU
Surge Protection 600 Watt transient voltage suppression on all RS-232/485/422 and power lines
Indicators Power, RxD, TxD, Link and Collision LEDs

Optical Link Performance Data
820 nm Standard Power (Option M)
Temperature = +25 degrees C unless otherwise noted
Fiber Cable
(Multimode)
Typical
Output Power
(dBm)
Minimum
Receiver
Sensitivity
(dBm)
Maximum Link
Distance (Worst Case)
Maximum Link
Distance (Typical)
Kilometers Miles Kilometers Miles
50/125 µm -18.2 -25.4 .300 .190 1.50 0.93
62.5/125 µm -15.4 1.00 .620 2.50 1.55
100/140 µm -11.4 1.45 .900 3.33 2.07
200 µm HCS -5.9 1.35 .840 2.75 1.71

820 nm High Power (Option E)
Temperature = +25 degrees C unless otherwise noted
Fiber Cable
(Multimode)
Typical
Output Power
(dBm)
Minimum
Receiver
Sensitivity
(dBm)
Maximum Link
Distance (Worst Case)
Maximum Link
Distance (Typical)
Kilometers Miles Kilometers Miles
50/125 µm -15.2 -25.4 1.05 0.65 2.75 1.60
62.5/125 µm -11.4 2.00 1.24 3.93 2.44
100/140 µm -7.9 2.09 1.30 4.39 2.73
200 µm HCS -3.9 1.55 0.96 3.08 1.92
Notes:
1. Link distances are based on continuous fiber, no splices
2. Output power measured at the end of 1 meter of optical fiber with large area detector.
3. Input sensitivity measured at the end of the fiber optic cable with large area detector.
4. Includes a 3dB optical safety margin to account for aging.

650 nm (Option A and T)
Temperature = 0 to +70 degrees C unless otherwise noted
Fiber Cable
(Multimode)
Typical Output Power
(dBm)
Minimum Receiver
Sensitivity (dBm)
Maximum Link
Distance (Worst Case)
Meters Feet
200 µm HCS -18.0 -23.0 200 656
1mm POF -7.5 -21.6 48 158
Notes:
1. Link distances are based on continuous fiber, no splices
2. Output power measured at the end of 0.5 meters of optical fiber with large area detector.
3. Input sensitivity measured at the end of the fiber optic cable with large area detector.
4. 1mm POF 0.23dB/m worst case attenuation.
5. HCS 10dB/km worst case attenuation.
6. Includes a 3dB optical safety margin for POF.
7. Includes a 2dB optical safety margin for HCS.

Order Options

 © Copyright 2006 dutec.
www.dutec.net